Product

00

Search product

Usage

















Target gas

























Category




Applicable Products:
Gas Sensor

SB-11A-00

Usage:Home gas leak detector/Industrial leak detector
Target gas:LNG(Methane)/LPG(Propane, butane)/H2
Target gas LNG(Methane),LPG(Propane, butane),H2
Description Compact, low power consumption, excellent responsiveness, and highly sensitive sensor for various hydrocarbons.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-11A-00
Related item
Gas Sensor

SB-12A-00

Usage:Home gas leak detector/Industrial leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane),H2
Description Compact, low power consumption sensor with excellent methane selectivity.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Charcoal filter
Size φ10.0 x 20mm
Weight 1.2g
SB-12A-00
Related item
FIS3031-xx
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-15-00

Usage:Industrial leak detector
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Compact, low power consumption, excellent responsiveness, and highly sensitive sensor for propane LPG/butane
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-15-00
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-500-12

Usage:Home gas leak detector/Industrial leak detector
Target gas:CO
Target gas CO
Description Sensor with high sensitivity and long life to carbon monoxide. UL compliant product
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V x 5sec. + DC 0.2V x 20sec. 
Circuit voltage/less than DC 5V
Power consumption Average:34mW
Filter Charcoal filter
Size φ10.0 x 20mm
Weight 1.2g
SB-500-12
Related item
FIS3051-xx
SCK-03
Gas Sensor

SB-95-12

Usage:Home gas leak detector/Industrial leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description A sensor that can selectively detect methane and CO only with one sensor element. UL compliant product
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V x 5sec. + DC 0.2V x 20sec. 
Circuit voltage/less than DC 5V
Power consumption Average:34mW
Filter Charcoal filter
Size φ10.0 x 20mm
Weight 1.2g
SB-95-12
Related item
FIS3001-xx
SCK-03
Gas Sensor

SB-19-00

Usage:Industrial leak detector
Target gas:H2
Target gas H2
Description Compact, low power consumption sensor with excellent H2 selectivity.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-19-00
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-42A-00

Usage:Refrigerant gas/Industrial leak detector
Target gas:Refrigerant(R32/R410a/R407C/R1234yf/R454B/R454C/Others)
Target gas Refrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
Description Compact, low power consumption, highly responsive sensor that is highly sensitive to various refrigerant gases.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-42A-00
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-43A-00

Usage:Refrigerant gas/Industrial leak detector
Target gas:Refrigerant(R32/R410a/R407C/R1234yf/R454B/R454C/R290/Others)
Target gas Refrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
Description Compact sensor that is highly sensitive to various refrigerant gases with low power consumption and excellent durability
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Silica filter
Size φ10.0 x 20mm
Weight 1.2g
SB-43-00
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-53-01

Usage:Research・Analysis - Enviromental measurement
Target gas:Ammonia
Target gas Ammonia
Description Compact sensor that is highly sensitive to ammonia with low power consumption and excellent response
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-53-00
Related item
FIS3091-xx
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-AQ1-06

Usage:Automobile - Inside air/Air quality - Air purifiers
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Compact sensor that is highly sensitive to gas generated in a living space with low power consumption and excellent response
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-AQ1-06
Related item
FIS3072-xx
EVM-SB-01-xx
SCK-03
Gas Sensor

SB-30-04

Usage:Alcohol checker
Target gas:Ethanol/VOC/Halitosis
Target gas VOC、Breath gas
Description Sensor that is highly stable after power-on and highly sensitive to alcohol and various VOCs. Suitable for intermittent operation products.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 0.9V ± 5% Circuit voltage/less than DC 5V
Power consumption 120mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SB-30-04
Related item
EVM-SB-01-xx
SCK-03
Gas Sensor

SP-11-00

Usage:Home gas leak detector
Target gas:LNG(Methane)/LPG(Propane, butane)/H2
Target gas LNG(Methane),LPG(Propane, butane),H2
Description Sensor that is highly sensitive to various hydrocarbons. Circuit design is easier than SB- series.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption 400mW
Filter Not included
Size φ17.0 x 16.5mm
Weight 1.75g
SP-11-00
Related item
EVM-SP-01-xx
Gas Sensor

SP-31-00

Usage:Industrial leak detector
Target gas:Ethanol/VOC
Target gas Ethanol、VOC
Description Sensor that is highly sensitive to various VOCs. Circuit design is easier than SB- series.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption 400mW
Filter Not included
Size φ17.0 x 16.5mm
Weight 1.75g
SP-31-00
Related item
EVM-SP-01-xx
Gas Sensor

SP-42A-00

Usage:Refrigerant gas/Industrial leak detector
Target gas:Refrigerant(R32/R410a/R407C/R1234yf/R454B/R454C/Others)
Target gas Refrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
Description Sensor with excellent response and high sensitivity to various refregerant gases. Circuit design is easier than SB- series.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption 400mW
Filter Not included
Size φ17.0 x 16.5mm
Weight 1.75g
SP-42A-00
Related item
EVM-SP-01-xx
Gas Sensor

SP-42AF-00

Usage:Refrigerant gas/Industrial leak detector
Target gas:Refrigerant(R32/R410a/R407C/R1234yf/R454B/R454C/Others)
Target gas Refrigerant gas(R32/R410a/R407C/R1234yf/R454C/R454B/R22)
Description Sensor with high durability and high sensitivity to various refrigerant gases. Circuit design is easier than SB- series.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption 400mW
Filter Silica filter
Size φ17.2 x 23.3mm
Weight 3.4g
SP-42AF-00
Related item
EVM-SP-01-xx
Gas Sensor

SP3S-AQ2-01

Usage:Automobile - Inside air/Air quality - Air purifiers/Home appliances/Alcohol checker
Target gas:CO/Ethanol/VOC
Target gas CO、Ethanol、VOC
Description Compact sensor that is highly sensitive to gas generated in a living space. Circuit design is easier than SB- series.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption 400mW
Filter Not included
Size φ7.6 x 13.4mm
Weight 0.6g
SP3S-AQ2-01
Related item
EVM-SP-02-SP3S
Gas Sensor

SP3-61-00

Usage:Air quality - Ozone/Home appliances
Target gas:Ozone
Target gas Ozone
Description Sensor that is highly sensitive to ozone. Circuit design is easier than SB- series.
Sensing principal Semiconductor type
Standard operating condition Heater voltage/DC 5.0V ± 4% Circuit voltage/less than DC 5V
Power consumption 400mW
Filter Not included
Size φ14.0 x 18.0mm
Weight 1.2g
SP3-61-00
Related item
A01020-61
A1320301-SP361-02
Sensor Module

EVM-SB-01-xx

Usage:-
Target gas:-
Description Evaluation module for SB series sensor. (except SB-500-12,SB-96-00,SB-95-12)
Sensing principal of mounted gas sensor Semiconductor type
Power supply DC5V ± 4%
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size Circuit board size:37×22㎜
Cable length:10㎝
EVM-SB-01-xx
Related item
Sensor Module

EVM-SP-01-xx

Usage:-
Target gas:-
Description Evaluation module for SP series sensor.
Sensing principal of mounted gas sensor Semiconductor type
Power supply DC5V ± 4%
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size Circuit board size:37×22㎜
Cable length:10㎝
EVM-SP-01-xx
Related item
Sensor Module

EVM-SP-02-SP3S

Usage:Automobile - Inside air/Air quality - Air purifiers/Alcohol checker
Target gas:-
Target gas CO、Ethanol、VOC
Description Evaluation module for SP3S-AQ2-01 to measure sensor output.
Sensing principal of mounted gas sensor Semiconductor type
Power consumption 210mW
Power supply DC5V ± 4%
Current consumption 42mA
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size 37×22×13.4(H)㎜
Cable length:10㎝
Weight 5g
EVM-SP-02-SP3S
Related item
SP3S-AQ2-01
Sensor Module

A1320301-SP61-02

Usage:Air quality - Ozone/Industrial leak detector
Target gas:Ozone
Target gas Ozone
Description Module for measuring ozone gas.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0 - 250 ppb
Power consumption 600mW
Power supply DC5V ± 5%
Current consumption 120mA
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size 51 (W) x 37 (D) x 22 (H) mm
Weight 15g
Sensor Module

A1320301-SP61-02F

Usage:Air quality - Ozone/Industrial leak detector
Target gas:Ozone
Target gas Ozone
Description Module for measuring ozone gas with fan and cable.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0 - 250 ppb
Power consumption 700mW
Power supply DC5V ± 5%
Current consumption 140mA
Signal output Voltage(0 - 5 V)
Waterproof case Not included
Size 65 (W) x 100 (D) x 35 (H) mm
Weight 90g
A1320301-SP61-02F
Related item
A1320301-SP61-02
Sensor Module

A01020-61

Usage:Air quality - Ozone
Target gas:Ethanol
Target gas Ozone
Description Evaluation module for SP3-61-00. This module is for sensor output measurement.
Size 22 x 37 x 13(H)mm
Weight 5g
A01020-61
Related item
SP3-61-00
その他

A051020H-001

Usage:Air quality - Ozone
Target gas:Ozone
Description Cable for ozone module.
   
 
Sensor Module

IR-93S-04/100

Usage:Automobile - Inside air/Air quality - Air purifiers/Air quality - CO2/Home appliances/
Target gas:CO2
Target gas CO2
Description Infrared absorption type CO2 sensor. High precision.
Sensing principal of mounted gas sensor Infrared type
Measurement range 400 - 5000 ppm
Power supply DC5V ± 10%
Signal output PWM
Size 64 (W) x 23 (D) x 10.7 (H) mm
Weight 13g
IR-93S-04/100
Related item
Sensor Module

FIS3001-00NC-03/50

Usage:Home gas leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description Gas calibrated module (mounted SB-95-12) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range CH4 0, 0.03-1 %
CO 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3001-00NC-03/50
Related item
SB-95-12
Sensor Module

FIS3001-00C4-03/50

Usage:Home gas leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description Gas calibrated module (mounted SB-95-12) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range CH4 0, 0.03-1 %
CO 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3001-00C4-03/50
Related item
SB-95-12
Sensor Module

FIS3031-00NC-50

Usage:Home gas leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane)
Description Gas calibrated module (mounted SB-12A) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3031-00NC-50
Related item
SB-12A-00
Sensor Module

FIS3031-00C4-50

Usage:Home gas leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane)
Description Gas calibrated module (mounted SB-12A) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3031-00C4-50
Related item
SB-12A-00
Sensor Module

FIS3051-00NC-03

Usage:Home gas leak detector
Target gas:CO
Target gas CO
Description Gas calibrated module (mounted SB-500-12) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3051-00NC-03
Related item
SB-500-12
Sensor Module

FIS3051-00C4-03

Usage:Home gas leak detector
Target gas:CO
Target gas CO
Description Gas calibrated module (mounted SB-500-12) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3051-00C4-03
Related item
SB-500-12
Sensor Module

FIS3062-00NC-20

Usage:Refrigerant gas/Home appliances
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Gas calibrated module (mounted SB-15C) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range Isobutane 0, 300-10000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3062-00NC-20
Related item
Sensor Module

FIS3062-00C4-20

Usage:Refrigerant gas/Home appliances
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Gas calibrated module (mounted SB-15C) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range Isobutane 0, 300-10000 ppm
Power supply DC5V ±5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3062-00C4-20
Related item
Sensor Module

FIS3072-00NC-10

Usage:-
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Gas calibrated module (mounted SB-AQ1) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3072-00NC-10
Related item
SB-AQ1-06
Sensor Module

FIS3072-00C4-10

Usage:-
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Gas calibrated module (mounted SB-AQ1) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3072-00C4-10
Related item
SB-AQ1-06
Sensor Module

FIS3082-00NC-50

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Refrigerant(R410a)
Target gas Refrigerant gas(R410a)
Description Gas calibrated module for R410a without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3082-00NC-50
Related item
Sensor Module

FIS3082-00C4-50

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Refrigerant(R410a)
Target gas Refrigerant gas(R410a)
Description Gas calibrated module for R410a with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3082-00C4-50
Related item
Sensor Module

FIS3091-00NC-03

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Ammonia
Target gas Ammonia
Description Gas calibrated module (mounted SB-53) without waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-500 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3091-00NC-03
Related item
SB-53-01
Sensor Module

FIS3091-00C4-03

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Ammonia
Target gas Ammonia
Description Gas calibrated module (mounted SB-53) with waterproof case. No concentration output.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-500 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3091-00C4-03
Related item
SB-53-01
Sensor Module

FIS3001-99NC-03/50

Usage:Home gas leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description Gas calibrated module (mounted SB-95-12) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range CH4 0, 0.03-1 %
CO 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3001-99NC-03/50
Related item
SB-95-12
Sensor Module

FIS3001-99C4-03/50

Usage:Home gas leak detector
Target gas:LNG(Methane)/CO
Target gas LNG(Methane)、CO
Description Gas calibrated module (mounted SB-95-12) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range CH4 0, 0.03-1 %
CO 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3001-99C4-03/50
Related item
SB-95-12
Sensor Module

FIS3031-99NC-30/50

Usage:Home gas leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane)
Description Gas calibrated module (mounted SB-12A) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3031-99NC-30/50
Related item
SB-12A-00
Sensor Module

FIS3031-99C4-30/50

Usage:Home gas leak detector
Target gas:LNG(Methane)
Target gas LNG(Methane)
Description Gas calibrated module (mounted SB-12A) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3031-99C4-30/50
Related item
SB-12A-00
Sensor Module

FIS3051-99NC-01/03

Usage:Home gas leak detector
Target gas:CO
Target gas CO
Description Gas calibrated module (mounted SB-500-12) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3051-99NC-01/03
Related item
SB-500-12
Sensor Module

FIS3051-99C4-01/03

Usage:Home gas leak detector
Target gas:CO
Target gas CO
Description Gas calibrated module (mounted SB-500-12) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3051-99C4-01/03
Related item
SB-500-12
Sensor Module

FIS3062-99NC-10/20

Usage:Refrigerant gas/Home appliances
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Gas calibrated module (mounted SB-15C) without waterproof case. Concentration output function included .
Sensing principal of mounted gas sensor Semiconductor type
Measurement range Isobutane 0, 300-10000 ppm
Power supply DC5V ±5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3062-99NC-10/20
Related item
Sensor Module

FIS3062-99C4-10/20

Usage:Refrigerant gas/Home appliances
Target gas:LPG(Propane, butane)
Target gas LPG(Propane, butane)
Description Gas calibrated module (mounted SB-15C) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range Isobutane 0, 300-10000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3062-99C4-10/20
Related item
Sensor Module

FIS3072-99NC-03/10

Usage:
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Gas calibrated module (mounted SB-AQ1) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3072-99NC-03/10
Related item
SB-AQ1-06
Sensor Module

FIS3072-99C4-03/10

Usage:
Target gas:H2/Ethanol/VOC
Target gas H2、Ethanol、VOC
Description Gas calibrated module (mounted SB-AQ1) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-1000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3072-99C4-03/10
Related item
SB-AQ1-06
Sensor Module

FIS3082-99NC-10/50

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Refrigerant(R410a)
Target gas Refrigerant gas(R410a)
Description Gas calibrated module for R410a without waterproof case. Concentration output function included .
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3082-99NC-10/50
Related item
Sensor Module

FIS3082-99C4-10/50

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Refrigerant(R410a)
Target gas Refrigerant gas(R410a)
Description Gas calibrated module for R410a with waterproof case. Concentration output function included .
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 0.03-1 %
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3082-99C4-10/50
Related item
Sensor Module

FIS3091-99NC-01/03

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Ammonia
Target gas Ammonia
Description Gas calibrated module (mounted SB-53) without waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-500 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Not included
Size 28 x 41 x 20 (H) mm
Weight 5g
FIS3091-99NC-01/03
Related item
SB-53-01
Sensor Module

FIS3091-99C4-01/03

Usage:Refrigerant gas/Home appliances/Industrial leak detector
Target gas:Ammonia
Target gas Ammonia
Description Gas calibrated module (mounted SB-53) with waterproof case. Concentration output function included.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 30-500 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 35mA
Signal output Concentration
Sensor
Alarm output
Waterproof case Included
Size 31×44×20 (H) mm
Weight 19g
FIS3091-99C4-01/03
Related item
SB-53-01
Sensor Module

FIS5084-01NC

Usage:Refrigerant gas/Home appliances
Target gas:Refrigerant(R32)
Target gas Refrigerant gas(R32)
Description IEC compliant product. Gas calibrated module (mounted SB-43A) without waterproof case.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 2000-10000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 40mA
Signal output Alarm output
Waterproof case Not included
Size 26 x 26 x 20(H)mm
Weight 5g
FIS5084-01NC
Related item
SB-43A-00
Sensor Module

FIS5084-01C1

Usage:Refrigerant gas/Home appliances
Target gas:Refrigerant(R32)
Target gas Refrigerant gas(R32)
Description IEC compliant product. Gas calibrated module (mounted SB-43A) with waterproof case.
Sensing principal of mounted gas sensor Semiconductor type
Measurement range 0, 2000-10000 ppm
Power supply DC5V ± 5%
Current consumption Average current consumption 40mA
Signal output Alarm output
Waterproof case Included
Size 53 x 30 x 23.5(H)mm
Weight 11g
FIS5084-01C1
Related item
SB-43A-00
その他

SCK-03

Usage:-
Target gas:-
Description Gas sensor socket for SB series, SP3S-AQ2-01, SP3-61
Size 12.6×7.4×10.6(H)㎜
Weight 1.3g
SCK-03
Related item
SB series
SP3S-AQ2-01
SP3-61-
Sensor Module

FH2-HY11

Usage:Fuel Cell/Industrial leak detector
Target gas:H2
Target gas H2
Description Hydrogen module that can be used for detecting with either battery power supply or commercial and industrial electric supply
Sensing principal of mounted gas sensor Catalytic type
Measurement range 0 ~ 4 vol.%
Power supply 5V ± 0.25V DC
Current consumption Approx. 0.25W
Signal output Analog
Size 35.2 (W) x 45.4 (D) x 20.25 (H) mm
Weight 24g
FH2-HY11
Related item
Sensor Module

FH2-HY04-GS2

Usage:Automobile - Fuel Cell
Target gas:H2
Target gas H2
Description Sensor module for detecting hydrogen leakage from fuell cell vehicle (FCV).
Sensing principal of mounted gas sensor Catalytic type
Measurement range 0 ~ 4 vol.%
Power supply 12V (9 ~ 16V) DC
Power consumption ≤1000mW
Signal output PWM
IP code IP6K7
Size 82.6 (W) x 80.8 (D) × 22.5 (H) mm
Weight 58g
FH2-HY04-GS2
Related item
Sensor Module

FH2-HY05-GS1

Usage:Automobile - Fuel Cell
Target gas:H2
Target gas H2
Description Sensor module for detecting hydrogen leakage from fuell cell vehicle (FCV).
Sensing principal of mounted gas sensor Catalytic type
Measurement range 0 ~ 4 vol.%
Power supply 12V (9 ~ 16V) DC
Current consumption Approx. 1.0W
Signal output CAN
Standard CAN ID 20A,202
Waterproof case Not included
Size 62 (W) x 49 (D) × 22.5 (H) mm
Weight 60g
FH2-HY05-GS1
Related item
Sensor Module

FH2-HY06-GS2

Usage:Automobile - Fuel Cell
Target gas:H2
Target gas H2
Description Sensor module for detecting hydrogen leakage from fuell cell vehicle (FCV).
Sensing principal of mounted gas sensor Catalytic type
Measurement range 0 ~ 4 vol.%
Power supply 24V (16~32V) DC
Power consumption ≤500mW
Signal output CAN
Standard CAN ID 0x0CFF1C90, 0x0CFF1C91
IP code IP6K7
Size 82.6 (W) x 80.8 (D) × 22.5 (H) mm
Weight 60g
FH2-HY06-GS2
Related item
Application

OralChroma CHM-2

Usage:Breath analysis - Oral Chroma
Target gas:Sulfide (Methyl mercaptan・ Dimethyl sulfide)/Hydrogen sulfide
Target gas Hydrogen sulfide, Methyl mercaptan, Dimethyl sulfide
Description This device separates VSC in 3 element gases and measures its concentration. UL/CE compliant product.
Measurement range Hydrogen sulfide 50 - 1000 ppb
Methyl mercaptan 50 - 1000 ppb
Dimethyl sulfide 50 - 1000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V 
Current consumption 27VA (Max.60VA)
Signal output USB/Bluetooth
Size 280 (W) x 385 (D) x 170 (H)
Weight 4kg
OralChroma CHM-2
Related item
Application

SGC(Sensor Gas Chromatograph)
ODSA-P3-A

Usage:Research・Analysis - Enviromental measurement/Breath analysis - Others
Target gas:Sulfide (Methyl mercaptan・ Dimethyl sulfide)/Hydrogen sulfide
Target gas Hydrogen sulfide, Methanethiol, Dimethyl sulfide
Description Hydrogen sulfide, methanethiol, and dimethyl-sulfide can be separated and detected at the ppb level without concentrating the sample.
Measurement range Hydrogen sulfide 2-1000 ppb
Methanethiol 5-1000 ppb
Dimethyl sulfide 5-1000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 2cc
Power supply AC 100V  or AC 220V
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×340(D)mm
Weight 5.5kg
SGC(Sensor Gas Chromatograph) ODSA-P3-A
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
ODNA-P3-A

Usage:Research・Analysis - Enviromental measurement
Target gas:Ammonia
Target gas Ammonia
Description Ammonia can be detected at the ppb level without concentrating sample.
Measurement range Ammonia 30-10000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 2cc
Power supply AC 100V  or AC 220V
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×340(D)mm
Weight 5.5kg
SGC(Sensor Gas Chromatograph) ODNA-P3-A
Related item
Application

SGC(Sensor Gas Chromatograph)
ODNA-P3-B

Usage:Research・Analysis - Enviromental measurement
Target gas:Trimethylamine
Target gas Trimethylamine
Description Trimethylamine can be separated and detected at the ppb level without concentrating sample.
Measurement range Trimethylamine 10-10000 ppb
Measuring time 8 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 2cc
Power supply AC 100V  or AC 220V
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×340(D)mm
Weight 5.5kg
SGC(Sensor Gas Chromatograph) ODNA-P3-B
Related item
Application

SGC(Sensor Gas Chromatograph)
SGHA-P3-A

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:H2/CO
Target gas H2、CO
Description H2 and CO can be separated and detected at the ppb level without concentrating sample. (for low concentration)
Measurement range H2 10-10000 ppb
CO 50-10000 ppb
Measuring time 2 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V  or AC 220V
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×340(D)mm
Weight 5.5kg
SGC(Sensor Gas Chromatograph) SGHA-P3-A
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGHA-P3-B

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement/Breath analysis - Others
Target gas:H2/CO
Target gas H2、CO
Description H2 and CO can be separated and detected at the ppm level without concentrating sample. (for high concentration)
Measurement range H2 1000-100000 ppb
CO: 1000-100000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V  or AC 220V
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×340(D)mm
Weight 5.5kg
SGC(Sensor Gas Chromatograph) SGHA-P3-B
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGEA-P3-A

Usage:Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement/Breath analysis - Others
Target gas:Ethanol/Halitosis/Acetaldehyde/Acetone/Isoprene
Target gas Acetone、Ethanol、Acetaldehyde、Isoprene
Description Acetone, ethanol, acetaldehyde and isoprene can be seperated and detected at the ppb level without cocentrating sample.
Measurement range Acetone 20-50000 ppb
Ethanol 200-100000 ppb
Acetaldehyde 5-10000 ppb
Isoprene 10-10000 ppb
Measuring time 8 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 5cc
Power supply AC 100V 
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×435(D)mm
Weight 6.5kg
SGC(Sensor Gas Chromatograph) SGEA-P3-A
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGEA-P3-B

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:Acetaldehyde
Target gas Acetaldehyde
Description Acetaldehyde can be detected at the ppb level without cocentrating sample.
Measurement range Acetaldehyde 5-10000 ppb
Measuring time 8 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 5cc
Power supply AC 100V 
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×435(D)mm
Weight 6.5kg
SGC(Sensor Gas Chromatograph) SGEA-P3-B
Related item
Exhaled breath bag
Application

SGC(Sensor Gas Chromatograph)
SGEA-P3-C1

Usage:Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:Ethylene
Target gas Ethylene
Description Ethylene can be detected from 5 ppb without concentrating sample
Measurement range Ethylene 5-10000 ppb
Measuring time 4 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 5cc
Power supply AC 100V 
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×435(D)mm
Weight 6.5kg
SGC(Sensor Gas Chromatograph) SGEA-P3-C1
Related item
Application

SGC(Sensor Gas Chromatograph)
SGEA-P3-C2

Usage:Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:Ethylene/Acetaldehyde
Target gas Ethylene、Acetaldehyde
Description Ethylene and acetaldehyde can be seperated and detected at the ppb level without cocentrating sample.
Measurement range Ethylene 50-10000 ppb
Acetaldehyde 100-10000 ppb
Measuring time 8 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 5cc
Power supply AC 100V 
Current consumption Approx. 100VA  
Signal output USB
Size 260(W)×135(H)×435(D)mm
Weight 6.5kg
SGC(Sensor Gas Chromatograph) SGEA-P3-C2
Related item
Application

PDHA-1000、PDHA-2000、PDHA-3000

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:H2
Target gas H2
Description This device can analyze the temperature desorption of H2 at the ppb level, from room temperature to 600℃ (with PDHA-1000), 800℃(with PDHA-2000),1000℃(with PDHA-3000)under atmospheric pressure
Measurement range H2 10-10000 ppb
Measuring time 2 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V 
Current consumption Approx. 1000VA(Total)
Signal output USB
Size 260(W)×135(H)×340(D)mm, other Please refer to the catalog
Weight Please refer to the catalog
PDHA-1000、PDHA-2000、PDHA-3000
Related item
Application

PDHA-4000

Usage:Automobile - Others/Research・Analysis - Enviromental measurement/Research・Analysis - Hydrogen embrittlement
Target gas:H2
Target gas H2
Description PDHA-4000 can analyze the temperature desorption of H2 at the ppb level, from -100℃ to 800℃ under atmospheric pressure
Measurement range H2 10-10000 ppb
Measuring time 2 min.
Carrier gas Filtered clean ambient air
Detector Semiconductor gas sensor
Sampling gas amount 1cc
Power supply AC 100V 
Current consumption Approx. 1000VA(Total)
Signal output USB
Size 260(W)×135(H)×340(D)mm, other Please refer to the catalog
Weight Please refer to the catalog
PDHA-4000
Related item

In the interest of continued product improvement, we reserve the right to change design features without prior notice.